{{Tuto Step
 
{{Tuto Step
|Step_Title=Step 2 - Ignition and configuration
+
|Step_Title=Allumage et paramétrage
 
|Step_Content=Press the PWR button. The locator emits a continuous or pulsed signal depending on the setting selected with the MOD button.
 
|Step_Content=Press the PWR button. The locator emits a continuous or pulsed signal depending on the setting selected with the MOD button.
 
|Step_Picture_00=Visual_location_of_defects_on_optical_fiber_img73.jpg
 
|Step_Picture_00=Visual_location_of_defects_on_optical_fiber_img73.jpg

Revision as of 14:49, 7 June 2019

Author avatarAlexiane Philip | Last edit 15/01/2020 by Sysop under review

Localiser un défaut sur une fibre optique et identifier des liens grâce au VFL TED Equipement.

Step 1 - Règle de sécurité

Le localisateur visuel de défauts (ou crayon optique) émet une lumière rouge à une puissance de sortie de 10 mW. Ne pas visualiser directement le faisceau lumineux ou le diriger vers une autre personne. Replacer systématiquement le bouchon de protection après usage.


N'allumer l'appareil que lorsque le bouchon de protection est en place ou qu'un connecteur est fixé sur la sortie.


Step 2 - Allumage et paramétrage

Press the PWR button. The locator emits a continuous or pulsed signal depending on the setting selected with the MOD button.




Step 3 - Step 3 - Connection to the fibre

The visual defect locator is compatible with all connectors with a 2.5 mm ferrule. For 1.25 mm ferrules, the use of an adapter is required.


Step 4 - Step 4 - Identify the length of the fibre

The locator can be used on links up to 10 km. Beyond that, whatever the power of an optical pencil, the light beam cannot be perceived.



Step 5 - Step 5 - Locating the end

The end of an optical link is detected by the presence of the light signal. This is a function widely used for mixing garters in street cabinets or bays.




Step 6 - Step 6 - Locating the defect (a curve for example)

Due to the high reflection of the light as it passes through a stress (macro-curve) or when a fibre is cut, this device is widely used to correct defects (which cause significant optical losses), on the visible part of the fibres.



Step 7 - Step 7 - Turn off the device

After using the device, turn off the locator and place the protective cap on the optical output.