|Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":-46,"top":0,"width":800,"height":444,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1.02,"scaleY":1.02,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"http://demo-master.dokit.io/w/images/b/bb/Photometric_Measurement_img15.jpg","filters":[]}],"height":449.4339622641509,"width":600}
 
|Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":-46,"top":0,"width":800,"height":444,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1.02,"scaleY":1.02,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"http://demo-master.dokit.io/w/images/b/bb/Photometric_Measurement_img15.jpg","filters":[]}],"height":449.4339622641509,"width":600}
|Description=<translate>Perform a photometric measurement at the FTTH network subscriber's home.</translate>
+
|Description=<translate><!--T:1-->
 +
Perform a photometric measurement at the FTTH network subscriber's home.</translate>
 
|Categories=Work instructions
 
|Categories=Work instructions
 
|Difficulty=Easy
 
|Difficulty=Easy
Line 14: Line 15:
 
|Introduction=<translate></translate>
 
|Introduction=<translate></translate>
 
}}
 
}}
{{TutoVideo
+
{{Materials
|VideoType=Mp4
+
|ItemList={{ItemList
 +
|Item=Photometer
 +
}}
 
}}
 
}}
{{Materials}}
 
 
{{Tuto Step
 
{{Tuto Step
|Step_Title=<translate>Switch on and configure the device</translate>
+
|Step_Title=<translate><!--T:2-->
|Step_Content=<translate>After switching on the device, check and set the measuring wavelength to 1490 nm, the wavelength of the downlink flow, if necessary.
+
Switch on and configure the device</translate>
 
+
|Step_Content=<translate><!--T:3-->
 +
After switching on the device, check and set the measuring wavelength to 1490 nm, the wavelength of the downlink flow, if necessary.
  
 +
<!--T:4-->
 
Set the unit of measurement to dBm as stipulated in the operators' procedures.</translate>
 
Set the unit of measurement to dBm as stipulated in the operators' procedures.</translate>
 
|Step_Picture_00=Photometric_Measurement_img63.jpg
 
|Step_Picture_00=Photometric_Measurement_img63.jpg
Line 32: Line 36:
 
}}
 
}}
 
{{Tuto Step
 
{{Tuto Step
|Step_Title=<translate>Connecting the equipment</translate>
+
|Step_Title=<translate><!--T:5-->
|Step_Content=<translate>Use the optical garter that connects the optical terminal socket (OTS) to the customer's optical fibre box (OFB) to perform the measurement.
+
Connecting the equipment</translate>
 
+
|Step_Content=<translate><!--T:6-->
 +
Use the optical garter that connects the optical terminal socket (OTS) to the customer's optical fibre box (OFB) to perform the measurement.
  
 +
<!--T:7-->
 
Clean the surface of the optical connectors at the first end of the garter and OTS with a cleaning pen. Connect the optical garter to the OTS. Proceed in the same way for the connector at the other end and connect it to the photometer.
 
Clean the surface of the optical connectors at the first end of the garter and OTS with a cleaning pen. Connect the optical garter to the OTS. Proceed in the same way for the connector at the other end and connect it to the photometer.
  
 +
<!--T:8-->
 
<br /></translate>
 
<br /></translate>
 
|Step_Picture_00=Photometric_Measurement_img69.jpg
 
|Step_Picture_00=Photometric_Measurement_img69.jpg
Line 43: Line 50:
 
}}
 
}}
 
{{Tuto Step
 
{{Tuto Step
|Step_Title=<translate>Reading the signal strength</translate>
+
|Step_Title=<translate><!--T:9-->
|Step_Content=<translate>The measurement of the optical power is read directly from the photometer.
+
Reading the signal strength</translate>
 
+
|Step_Content=<translate><!--T:10-->
 +
The measurement of the optical power is read directly from the photometer.
  
 +
<!--T:11-->
 
The value should generally be between -16 dBm and -24 dBm.
 
The value should generally be between -16 dBm and -24 dBm.
  
 
+
<!--T:12-->
 
After the measurement, connect the garter to the customer's box (or at the test OFB).</translate>
 
After the measurement, connect the garter to the customer's box (or at the test OFB).</translate>
 
|Step_Picture_00=Photometric_Measurement_img84.jpg
 
|Step_Picture_00=Photometric_Measurement_img84.jpg

Latest revision as of 16:43, 7 June 2019

Author avatarAlexiane Philip | Last edit 7/06/2019 by Alexiane under review

Perform a photometric measurement at the FTTH network subscriber's home.
Difficulty
Easy
Duration
5 minute(s)
Area
Use
Business
Training
Other languages:
English

Step 1 - Switch on and configure the device

After switching on the device, check and set the measuring wavelength to 1490 nm, the wavelength of the downlink flow, if necessary.

Set the unit of measurement to dBm as stipulated in the operators' procedures.


Step 2 - Connecting the equipment

Use the optical garter that connects the optical terminal socket (OTS) to the customer's optical fibre box (OFB) to perform the measurement.

Clean the surface of the optical connectors at the first end of the garter and OTS with a cleaning pen. Connect the optical garter to the OTS. Proceed in the same way for the connector at the other end and connect it to the photometer.





Step 3 - Reading the signal strength

The measurement of the optical power is read directly from the photometer.

The value should generally be between -16 dBm and -24 dBm.